The testo 175 T2 temperature data logger has a large dispay and alarm indication that makes it ideal for continuous monitoring of temperatures. The temperature measurement logger has both an internal NTC thermistor, as well as capability for an external NTC probe connection, which allows for simultaneous measurements of ambient and product temperatures. Creation of Excel Spreadsheets, PDFs, and data analysis are all easily achieved with the free, downloadable ComSoft software.
 
Product Features:

• High accuracy internal NTC thermistor sensor for reliable data
• External NTC probe port compatible with a variety of different probe types
• Data transfer possible using the USB port, or SD card (Optional)
• Easy to read large display that shows current reading and exceeded measurement limits
• IP65 proection class
• Capable of CFR 21 Part 11 Compliancy
• Free data logger software available for download
• Data is secured within the logger, and can be password protected using ComSoft
• Includes lockable wall mount to prevent theft or tampering
 
*** Send your inquiry to get the final prices.  

Testo 175 T2 - Temperature Data Logger

Temperature - NTC Technical Data:
 
  • Measuring Range:
-35 to +55 °C internal
-40 to +120 °C external
  • Accuracy: 
internal: ±0.5 °C (-35 to +55 °C)
external: ±0.3 °C (-40 to +120 °C)
  • Resolution: 0.1 °C
 
General Technical Data
 
  • Dimensions: 89 x 53 x 27 mm
  • Operating temperature: -35 to +55 °C
  • Protection class: IP65
  • Channels: 1 external; 1 internal
  • Standards: EN 12830
  • Warranty: 2 years
  • Battery type: 3 x AIMn type AAA or Energizer
  • Battery life: 3 years (15 min. meas. rate, +25 °C)
  • Memory: 1,000,000 measuring values
  • Storage temperature: -35 to +55 °C 

Testo 175 T2 - Temperature Data Logger

Areas of Application:

• Monitoring and documentation of the temperature in cold storage rooms

Many foodstuffs or medicines have to be stored within a certain cold temperature range. This may be in individual refrigerated storage rooms, but also in specialised cold storage warehouses or high bay cold store warehouses. The temperature has to be documented in all of these refrigerated facilities, as strict regulations apply to quality management both in the food processing and medicine industries.
Data loggers are usually placed at the 'Critical Control Points' (CCPs) of a cold storage room to enable any fluctuations in temperature to be detected and appropriate action to be taken. Critical places include doors or passages into other temperature zones within a warehouse.

• Monitoring the temperature in frozen food storage areas

There are many facilities where (deep) frozen foods need to be stored. These range from individual freezer rooms at small food manufacturers (e.g. butchers), restaurants and supermarkets, freezer rooms in the food processing industry, right through to specialised cold storage warehouses/high bay freezer warehouses. In all of these facilities, the temperature has to be documented continuously. In Europe, only temperature recording devices that comply with EN 12830 are allowed to be used.

Data loggers are typically used to measure the air temperature in these kinds of storage facilities. The measuring instrument is positioned within the freezer room at the critical places where possible, such as by doors or refrigeration units, where it records temperature data at specified intervals (typically: every 15 minutes).
 
With the aid of special software, the recorded data can consequently be analysed and stored.

• Monitoring and documentation of storage temperatures

The proper observance of storage temperatures is an important prerequisite for the quality control of many products; e.g. in the area of foodstuffs and pharmaceutical products.

Data loggers are usually used for this purpose. They monitor and document the course of ambient temperature automatically, thereby contributing significantly to verifying that product quality is being maintained.

The direct display of violations of limit values allows fluctuations in temperature to be responded to fast. With the aid of the configuration and read out software, custom measurement configurations can also be made and recorded measurement data can be both analysed and stored.

• Monitoring and documentation of transit temperatures

The smooth recording and documentation of measurement data plays a significant role for all products that are sensitive to temperature fluctuations, or which need to be stored in a predesignated area.

The wrong temperature conditions during transportation can result in major losses in quality right through to a complete loss of value for the monitored products.
 
With the aid of a data logger, goods in transit can be monitored to make sure specified temperature zones are being observed; this can then be read out, analysed and stored using special software.

Waterproof immersion/penetration probe (NTC) – measuring range: -50 to +150 °C

Part No. 0613 1212
The waterproof immersion/penetration probe with NTC sensor records the temperature in liquids and semi-solid media quickly and accurately.
Key Features:
• NTC temperature sensor
• Waterproof
• Measuring accuracy of up to ±0.2 °C
• Measuring range: -50 to +150 °C
 

Robust air temperature probe (NTC) – measuring range: -50 to +125 °C

Part No. 0613 1712
Use the robust air temperature probe with exposed sensor (NTC) to measure air temperature with a short response time. It can be connected to a wide range of measuring instruments.
Key Features:
• Short response time thanks to the exposed sensor
• High level of accuracy of up to ±0.2 °C
• Measuring range: -50 to +125 °C
• NTC temperature sensor
 

Waterproof surface temperature probe (NTC) for flat surfaces - measuring range: -50 to +150 °C

Part No. 0613 1912
Thanks to its NTC sensor, the waterproof surface temperature probe delivers reliable, accurate measurement results even at low temperatures. For measurements on flat surfaces.
Key Features:
• NTC temperature sensor
• Measuring accuracy of up to ±0.2 °C
• Ideal for measurements on refrigeration systems, in cold storage warehouses/rooms or outdoors
• Measuring range: -50 to +150 °C
 

Stainless steel food probe (NTC) – measuring range: -50 to +150 °C

Part No. 0613 2211
Ideal for measuring the temperature of food: the temperature probe is made of hygienic stainless steel, is easy to clean and waterproof in accordance with IP65. 
Key Features:
• Precision NTC temperature sensor
• Made of hygienic stainless steel, waterproof according to IP65
• Short response time of 8 seconds
• Measuring range: -50 to +150 °C
 

Robust food penetration probe (NTC) – measuring range -25 to +150 °C

Part No. 0613 2411
The robust food penetration probe (with a corresponding measuring instrument) enables the measurement of core food temperatures.
Key Features:
• NTC temperature sensor
• EN 13485 and HACCP-compliant
• With special handle, reinforced PUR cable
• Measuring range: -25 to +150 °C
 

Frozen food probe (NTC) for screw-in use without pre-drilling – measuring range -50 to +140 °C

Part No. 0613 3211
The frozen food probe (with a corresponding measuring instrument) enables core temperatures to be measured in frozen food.
Key Features:
• NTC temperature sensor
• Can be screwed directly into frozen food, no pre-drilling required
• EN 13485 and HACCP-compliant
• Measuring range: -50 to +140 °C
 

Waterproof stainless steel food probe (NTC) – measuring range -50 to +150 °C

Part No. 0613 3311
The waterproof stainless steel food probe (with the appropriate measuring instrument) enables the measurement of the core temperature of foods.
Key Features:
• NTC temperature sensor
• EN 13485 and HACCP-compliant, water-protected according to IP 67
• Measuring range: -50 to +150 °C
• Heat-resistant probe cable
 

Pipe wrap probe with Velcro for pipe diameter to max. 75 mm, Tmax. +75 °C, NTC

Part No. 0613 4611
Pipe wrap probe with Velcro for pipe diameter to max. 75 mm, Tmax. +75 °C, NTC
Key Features:
• With Velcro: makes it easy to attach the surface probe to pipes with a pipe diameter of up to 75 mm
• NTC temperature probe with cable
• Measuring range: -50 to +70 °C 

Penetration probe NTC with ribbon cable, cable length 2 m, IP 54

Part No. 0572 1001
Penetration probe NTC with ribbon cable, cable length 2 m, IP 54
Key Features:
• NTC probe with exceptionally flat cable (2 m long), which can be pushed through narrow openings, e.g. through slits in doors
• Temperature measurement in pastes and semi-solid media and also in liquids and air
• Measuring range: -40 to +125 °C
 

Accurate immersion/penetration probe, 6m cable, IP 67

Part No. 0610 1725
Accurate immersion/penetration probe, 6m cable, IP 67
Key Features:
• NTC probe with exceptionally long 6 m cable, can be installed for long-term measurements
• Temperature measurement in liquids, pastes and in air
• Measuring range: -35 to +80 °C
 

Accurate immersion/penetration probe, cable: 1.5 m long, IP 67

Part No. 0628 0006

Stationary probe with aluminium sleeve, IP 65

Part No. 0628 7503
Stationary probe with aluminium sleeve, IP 65
Key Features:
• NTC temperature probe with 2.4 m cable, can be installed at the measuring location for long-term measurements
• Temperature measurement in liquids, pastes and in air
• Measuring range: -30 to +90 °C
 

Wall surface temperature probe, e.g. to prove damage in building material

Part No. 0628 7507

Stub probe, IP 54

Part No. 0628 7510
Key Features:

• NTC temperature probe with short probe tube (stub probe)
• Temperature measurement in liquids, pastes and in air
• Measuring range: -20 to +70 °C

Probe for surface measurement

Part No. 0628 7516
Key Features:

• NTC temperature probe with 2 m cable, for long-term measurements it can be affixed using a screw for example
• Temperature measurement on flat surfaces
• Measuring range: -50 to +80 °C

Wall holder (black) with lock for testo 175

Part No. 0554 1702

Cable for connecting the data loggers testo 175 and testo 176 to the PC, Mini-USB to USB

Part No. 0449 0047

SD card - for collecting the measurement data from the data loggers testo 175 and testo 176; 2 GB; application range to -20 °C

Part No. 0554 8803

Battery for testo 175

Part No. 0515 0009
Range of application to -10 °C, alkali manganese microcell AAA (please order 3 batteries per logger)

Battery for testo 175 - Application range below -10 °C, Energizer L92 microcells AAA

Part No. 0515 0042
(please order 3 batteries per logger) 

ComSoft Basic, Basic software

Part No. 0572 0580
ComSoft Basic, Basic software for programming and readout of Testo data loggers; graphic and tabular measurement value presentation as well as export function (if free download with registration not desired)

ComSoft Professional, Pro software incl. data archiving

Part No. 0554 1704

ComSoft CFR 21 Part 11, Software for requirements according to CFR 21 Part 11 for Testo data loggers

Part No. 0554 1705

ISO calibration certificate temperature probe; calibration points -18°C; 0°C; +40°C per channel/instrument

Part No. 0520 0153

DAkkS calibration certificate temperature Temp. data logger; cal. points -20°C; 0°C; +60°C; per channel/instrument

Part No. 0520 0261

Product Brochures

Download File Type Size  
Product Brochure Testo 175 T2 - Temperature Data Logger .pdf 720.6 KB Download

Instruction Manuals

Download File Type Size  
Instruction Manual Testo 175 T2 - Temperature Data Logger .pdf 1792.7 KB Download

Videos

No Record Found
 
 

Part Number : 0572 1752